Western Blot Substrates and Substrate Kits
Western Blot Substrates and Substrate Kits
- (4)
- (1)
- (1)
- (3)
- (1)
- (6)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (7)
- (1)
- (1)
- (2)
- (1)
- (7)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (9)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (5)
- (3)
- (4)
- (36)
- (1)
- (6)
- (1)
- (1)
- (2)
- (1)
- (2)
- (30)
- (26)
- (3)
- (1)
- (11)
- (4)
- (32)
- (2)
Filtered Search Results
Cytiva Amersham™ ECL Select™ Western Blotting Detection Reagent
Use as a high sensitivity reagent for chemiluminescent Western blotting detection. Cytiva Life Sciences™ Amersham™ ECL Select™ Western Blotting Detection Reagent provides highly intense signal output, for detection of medium to very low protein levels.
Cytiva Amersham™ ECL™ Prime Western Blotting Detection Reagent
Enables the use of highly diluted primary and secondary antibodies without reducing sensitivity. Cytiva Lifescience™ Amersham™ ECL™ Prime Western Blotting Detection Reagent produces high signal intensity and sensitivity.
Content And Storage | 2°C to 8°C |
---|---|
Sensitivity | ∼1 pg |
Product Type | ECL Western Blot Detection Reagent |
For Use With (Application) | Sensitive Quantitative or Confirmatory Western Blot |
Merck Immobilon™ Western Chemiluminescent HRP Substrate (ECL)
Provides high sensitivity over a broad detection range at an economical price
Substrate | Horseradish Peroxidase |
---|---|
Content And Storage | 2°C to 8°C |
Shelf Life | 9 Months |
For Use With (Application) | Dot/Slot Blot |
Thermo Scientific™ SuperSignal™ West Femto Maximum Sensitivity Substrate
Ultra-sensitive enhanced chemiluminescent (ECL) HRP substrate for low-femtogram-level detection by Western blot analysis.
Substrate | Horseradish Peroxidase |
---|---|
Form | Liquid |
Product Type | Substrate |
Signal Duration | 6 to 8 hr. |
Product Line | SuperSignal™ |
Detection Method | Chemiluminescence |
Thermo Scientific™ SuperSignal™ West Pico PLUS Chemiluminescent Substrate
Thermo Scientific SuperSignal West Pico PLUS Chemiluminescent Substrate is an enhanced chemiluminescent (ECL) horseradish peroxidase (HRP) substrate that enables picogram to high femtogram-level protein detection by western blot analysis.
Shipping Condition | Room Temperature |
---|---|
Substrate | Horseradish Peroxidase |
Recommended Antibody Concentrations | 2°: 1:20-100 K (10-50 ng/mL), 1°: 1:1 K (0.2-1 μg/mL) |
Conjugate | HRP |
Form | Liquid |
Product Type | Substrate |
Signal Duration | 6 to 24 hr. |
For Use With (Application) | Western Blot |
Product Line | SuperSignal™ |
Detection Method | Chemiluminescence |
Thermo Scientific™ Pierce™ ECL Western Blotting Substrate
Value-priced, entry-level peroxidase substrate for enhanced chemiluminescence (ECL) that directly replaces costlier products without the need to re-optimize conditions.
Substrate | Horseradish Peroxidase |
---|---|
Content And Storage | Upon receipt store at 2-8°C. Product is shipped at ambient temperature. |
Form | Liquid |
Product Type | Substrate |
Signal Duration | 1 to 2 hr. |
Product Line | Pierce™ |
Detection Method | Chemiluminescence |
Thermo Scientific™ 1-Step™ NBT/BCIP Substrate Solution
Powders and ready-made nitro-blue tetrazolium and 5-bromo-4-chloro-3'-indolyphosphate solutions for chromogenic detection of alkaline phosphatase probes.
Thermo Scientific™ SuperSignal™ West Atto Ultimate Sensitivity Substrate
SuperSignal™ West Atto Ultimate Sensitivity Substrate is an enhanced chemiluminescent (ECL) substrate for high attogram protein detection and provides the high level sensitivity and better signal-to-noise ratios compared to other commercially available horseradish peroxidase (HRP) substrates.
Shipping Condition | Wet Ice |
---|---|
Substrate | Horseradish Peroxidase |
Sensitivity | Low-femtogram to high-attogram |
Form | Liquid |
Product Type | Substrate |
Membrane Compatibility | Nitrocellulose, PVDF |
For Use With (Application) | Western Blot |
Product Line | SuperSignal™ |
Detection Method | Chemiluminescence |
Thermo Scientific™ 1-Step™ Ultra TMB-Blotting Solution
Thermo Scientific™ 1-Step Ultra TMB-Blotting Solution is an enhanced single-component horseradish peroxidase (HRP) substrate for Western blotting and immunohistochemistry.
Thermo Scientific™ SuperSignal™ West Dura Extended Duration Substrate
Luminol-based enhanced chemiluminescence (ECL) horseradish peroxidase (HRP) substrate ideal for quantitative western blotting with stable light output for mid-femtogram level detection for western blot analysis.
Substrate | Horseradish Peroxidase |
---|---|
Sensitivity | Mid-femtogram |
Form | Liquid |
Product Type | Substrate |
Signal Duration | 24 hr. |
Product Line | SuperSignal™ |
Detection Method | Chemiluminescence |
Thermo Scientific™ Pierce™ ECL Plus Western Blotting Substrate
Acridan-based chemiluminescent and chemifluorescent HRP substrate for Western blot detection using X-ray film or CCD- or laser-based imagers.
Sensitivity | Low picogram to mid-femtogram |
---|---|
Form | Liquid |
Product Type | Substrate |
Membrane Compatibility | Nitrocellulose, PVDF |
Product Line | Pierce™ |
Detection Method | Chemiluminescence, Fluorescence |
Thermo Scientific™ Pierce™ DAB Substrate Kit
Chromogenic horseradish peroxidase (HRP) substrate for Western blot and tissue staining methods.
Thermo Scientific™ Pierce™ CN/DAB Substrate Kit
Combines chloronaphthol- and diaminobenzidine-based HRP detection for Western blot and tissue staining methods.
Thermo Scientific™ 1-Step™ TMB-Blotting Substrate Solution
Ready-to-use blue TMB peroxidase (HRP) substrate specially formulated for chromogenic detection in Western blot and IHC experiments.
Thermo Scientific™ SuperSignal™ West Pico PLUS and SuperSignal™ West Femto Sample
Provides chemiluminescent detection substrates for both routine and high sensitivity western blots