Filtered Search Results
Conductivity Standards for METTLER TOLEDO Conductivity Probes, METTLER TOLEDO™
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Recommended NIST traceable solutions for calibrating or verifying METTLER TOLEDO conductivity electrodes.
Type | Conductivity Standard |
---|---|
For Use With (Equipment) | Conductivity Electrodes |
Recommended Storage | Ambient |
Solution Type | Conductivity Standard |
Thermo Scientific™ Eutech Handheld Meters Calibration Solution, 1413μS/cm KCl
Periodic calibration with accurate standards is recommended for meters
Conductivity Solution, Oakton™
Use this conductivity solution for accurate test results in the field or lab. Oakton™ Conductivity Solutions have KCl, NaCl and 442 conversions printed on the bottle for ease of use.
Type | Conductivity Standard |
---|---|
Chemical Name or Material | Cole-Parmer Conductivity Standards |
Traceable™ Conductivity Calibration Standards Certified Reference Material (CRM), NIST tested, Fisherbrand™
Use NIST-traceable reference materials for the highest accuracy available. Traceable™ Conductivity Calibration Standards Certified Reference Material (CRM) offer easy calibration with included instructions and temperature chart.
Type | Conductivity Standard |
---|---|
Packaging | Bottle |
Certifications/Compliance | ISO 17034 (1750.02) (formerly ISO Guide 34) Certified Reference Material |
Solution Type | Calibration Solution |
Traceable™ One-Shot™ Conductivity Calibration Standards Certified Reference Material Producer (CRM), Fisherbrand™
Ideal for lab or field applications
Packaging | 6/Pk. |
---|
Oakton™ Conductivity and TDS Standard
Oakton™ conductivity and TDS standards are traceable to NIST standard reference materials and ideal for laboratory and field analysis.
Thermo Scientific™ Eutech Handheld Meter Calibration Solution, 480 mL 111.8 mS/cm KCl
Periodic calibration with accurate standards is recommended for meter
Potassium chloride,≈0.000027M, Conductivity Standard, Thermo Scientific Chemicals
CAS: 7447-40-7 Molecular Formula: ClK Molecular Weight (g/mol): 74.55 MDL Number: MFCD00011360 InChI Key: WCUXLLCKKVVCTQ-UHFFFAOYSA-M PubChem CID: 4873 ChEBI: CHEBI:32588 SMILES: [Cl-].[K+]
PubChem CID | 4873 |
---|---|
CAS | 7447-40-7 |
Molecular Weight (g/mol) | 74.55 |
ChEBI | CHEBI:32588 |
MDL Number | MFCD00011360 |
SMILES | [Cl-].[K+] |
InChI Key | WCUXLLCKKVVCTQ-UHFFFAOYSA-M |
Molecular Formula | ClK |
Potassium chloride, 0.0375M, Conductivity Standard, Thermo Scientific Chemicals
CAS: 7447-40-7 Molecular Formula: ClK Molecular Weight (g/mol): 74.55 MDL Number: MFCD00011360 InChI Key: WCUXLLCKKVVCTQ-UHFFFAOYSA-M PubChem CID: 4873 ChEBI: CHEBI:32588 IUPAC Name: potassium chloride SMILES: [Cl-].[K+]
PubChem CID | 4873 |
---|---|
CAS | 7447-40-7 |
Molecular Weight (g/mol) | 74.55 |
ChEBI | CHEBI:32588 |
MDL Number | MFCD00011360 |
SMILES | [Cl-].[K+] |
IUPAC Name | potassium chloride |
InChI Key | WCUXLLCKKVVCTQ-UHFFFAOYSA-M |
Molecular Formula | ClK |
Conductivity Calibration Pouches, Oakton™
Calibrate on the go with these single-use 20mL calibration pouches. Oakton™ Conductivity Calibration Pouches are sealed to ensure freshness.
Type | Conductivity Standard |
---|---|
Quantity | 20 Single-use Pouches |
Chemical Name or Material | Cole-Parmer Conductivity Standards |
Potassium chloride, 0.0145M, Conductivity Standard, Thermo Scientific Chemicals
CAS: 7447-40-7 Molecular Formula: ClK Molecular Weight (g/mol): 74.55 MDL Number: MFCD00011360 InChI Key: WCUXLLCKKVVCTQ-UHFFFAOYSA-M PubChem CID: 4873 ChEBI: CHEBI:32588 SMILES: [Cl-].[K+]
PubChem CID | 4873 |
---|---|
CAS | 7447-40-7 |
Molecular Weight (g/mol) | 74.55 |
ChEBI | CHEBI:32588 |
MDL Number | MFCD00011360 |
SMILES | [Cl-].[K+] |
InChI Key | WCUXLLCKKVVCTQ-UHFFFAOYSA-M |
Molecular Formula | ClK |
Potassium chloride, 0.010M, Conductivity Standard, Thermo Scientific Chemicals
CAS: 7447-40-7 Molecular Formula: ClK Molecular Weight (g/mol): 74.55 MDL Number: MFCD00011360 InChI Key: WCUXLLCKKVVCTQ-UHFFFAOYSA-M PubChem CID: 4873 ChEBI: CHEBI:32588 SMILES: [Cl-].[K+]
PubChem CID | 4873 |
---|---|
CAS | 7447-40-7 |
Molecular Weight (g/mol) | 74.55 |
ChEBI | CHEBI:32588 |
MDL Number | MFCD00011360 |
SMILES | [Cl-].[K+] |
InChI Key | WCUXLLCKKVVCTQ-UHFFFAOYSA-M |
Molecular Formula | ClK |
TDS 442 Standard Solution, Eutech™
For TDS calibration and standards, choose from our available Eutech™'s TDS Standards, Calibrations, and Solutions
Type | TDS Standard |
---|---|
Color | Colorless |
Physical Form | Liquid |
pH | 7 |
Packaging | Plastic Bottle |
Quantity | 480 mL |
For Use With (Application) | Laboratory Use |
Solution Type | Standard Solution |
Conductivity Calibration Solution, 2764μS, Cole-Parmer™
500mL, Clear, None, 4.75 to 7.75, Liquid, Water Soluble, 0 to 10% KCl, NaCl, 90 to 100% Water